Technische Daten /
Specifications
|
LPN-BL 90 Blitzschutz
|
Lightning protector (Surge Protector) for coax line with N-female/N-female-long connectors, (bulkhead version to mount to any chassis) 90 V - max. 40 W
|
Frequenzbereich /
frequency range
|
0 - 2.7 GHz
|
Nennansprechgleich-spannung, max. Leistung/ nominal DC spark.over voltage, max. RF power
|
90 V / 40 W
|
Anschlüsse /
connector type
|
N-Buchse und lange N-Buchse /
N female and N female with long thread
|
Impedanz /
impedance
|
50 Ohm
|
Stoßstromfestigkeit nach IEC 61643-21 /
impuls discharge current acc. to IEC 61643-21
|
10 x 15 kA (8/20 µs)
2 x 2.5 kA (10/350 µs)
300 x 200 A (10/1000 µs)
5 x 20 A (1s @ 50 Hz)
|
Einfügedämpfung /
insertion loss
|
0.1 dB / 1 GHz
0.2 dB / 2.7 GHz
|
Rückflussdämpfung /
return loss
|
-30 dB / 1 GHz
-25 dB / 2 GHz
-23 dB / 2.7 GHz
|
Mittelpin /
center pin
|
versilbert /
silver plated
|
Oberfläche /
surface
|
vernickelt /
nickel plated
|
Betriebstemperatur /
operating temperature
|
-30°C bis / to +100°C
|
Schutzklasse /
protection class
|
IP 67 (IEC 60529)
|
Länge /
length
|
69 mm /
2.72 in.
|
Gewicht /
weight
|
ca. 173 g /
approx. 0.38 lb
|
TELEGÄRTNER-Nr. /
manufacturer code
|
alt / old: J01028A0044
neu / new: 100024248
|
Art.-Nr./Part No:
|
20600
|